Effect comparison of ultrasound-guided upper arm infusion port and thoracic infusion port in tumor chemotherapy patients
JIANG Wen-chuan1 JIANG Ya-lan2 LIANG Su-fang3
1.Department of Gastrointestinal Surgery,Jiangmen Central Hospital,Guangdong Province,Jiangmen 529000,China;
2.Department of Neurosurgery,Jiangmen Central Hospital,Guangdong Province,Jiangmen 529000,China;
3.Department of Neurology,Jiangmen Central Hospital,Guangdong Province,Jiangmen 529000,China
Abstract:Objective To explore the effect comparison of ultrasound-guided upper arm infusion port and thoracic infusion port in tumor chemotherapy patients.Methods A total of 100 tumor chemotherapy patients who needed to be implanted into the infusion port in Jiangmen Central Hospital from October 2018 to October 2019 were selected as the research subjects.They were divided into the control group (50 cases) and the observation group (50 cases) according to a random lottery method.The control group adopted a chest-type infusion port implantation treatment method,the observation group adopted an upper arm infusion port implantation treatment method.The total incidence of complications,postoperative comfort,the success rate of one needle placement,the incidence of vascular injury,and the rate of intraoperative hematoma formation of the two groups were compared.Results The total incidence of complications in the observation group was lower than that in the control group,the difference was statistically significant (P<0.05).The comfort scores of the observation group at 1 day,1 week,and 1 month after surgery were lower than those of the control group,and the comfort scores of the two groups at 1 week and 1 month after operation were lower than those of the control group 1 day after operation,the differences were statistically significant (P<0.05).The success rate of one-needle placement in the observation group was higher than that in the control group,and the incidence of vascular injury and intraoperative hematoma formation were lower than those in the control group,the differences were statistically significant (P<0.05).Conclusion Ultrasound-guided upper arm infusion port has high safety in cancer chemotherapy patients,and has high postoperative comfort,high success rate of one-needle placement,while has low incidence of vascular injury and intraoperative hematoma formation,clinical application value is high.
蒋文川;蒋雅兰;梁素芳. 超声引导下上臂输液港与胸式输液港在肿瘤化疗患者中的应用效果比较[J]. 中国当代医药, 2021, 28(4): 41-43转47.
JIANG Wen-chuan;JIANG Ya-lan;LIANG Su-fang. Effect comparison of ultrasound-guided upper arm infusion port and thoracic infusion port in tumor chemotherapy patients. 中国当代医药, 2021, 28(4): 41-43转47.