Abstract:ObjectiveTo analyze the clinical effect and impact factors of high intensity focused ultrasound in uterine myoma ablation,and to provide reference basis for improving clinical efficacy of uterine fibroids ablation.MethodsFifty patients with solitary uterine myoma from January to December 2014 were selected as observation objects.All patients were treated with HIFU.Clinical effect was evaluated according to postoperative contrast enhanced ultrasound,and the related factor that impact the application effect was evaluated.ResultsThe treatment was markedly effective in 28 cases (56.0%),effective in 20 cases(40.0%)and ineffective in 2 cases(4.0%).The age,target skin distance,the location of fibroids,fibroids type,fibroids volume of the patients with markedly effective treatment effect and had statistically significant differences compared with ineffective patients(P<0.01).ConclusionHigh intensity focused ultrasound in uterine fibroids ablation treatment has good application effect,but the age,the target skin distance,the location of fibroids,the type of fibroids,the volume of fibroids has a certain impact on the application effect of HIFU.
胡泊. 高强度聚焦超声在子宫肌瘤消融中的临床效果及影响因素研究[J]. 中国当代医药, 2017, 24(2): 70-72.
HU Bo. Study of the clinical effect and impact factors of high intensity focused ultrasound in uterine myoma ablation. 中国当代医药, 2017, 24(2): 70-72.