Application of ultrasound-guided double development line localization technique in radial artery puncture and catheterization in pediatric surgery patients
YE Li-qun PAN Jie-qiong
Department of Anesthesiology, People′s Hospital of Huaiji County, Guangdong Province, Huaiji 526400, China
Abstract:Objective To investigate the effect of ultrasound-guided double development line localization technique and blind probe touch technique on radial artery puncture and catheterization in pediatric surgery patients. Methods A total of 60 children with radial artery puncture and catheterization admitted to People′s Hospital of Huaiji County,Guangdong Province from October 2018 to September 2020 were selected as the study subjects. According to the random number table method, they were divided into the control group and the observation group, with 30 patients in each group. In the catheterization, blind probe and touch technology was used in the control group, and ultrasound-guided double development line positioning technology was used in the observation group. The first puncture success rate, puncture failure rate, puncture time and complications were compared between the two groups. Results The first puncture success rate in the observation group was higher than that in the control group,and the difference was statistically significant (P<0.05). The failure rate of puncture and catheterization in the observation group was lower than that in the control group, and the difference was statistically significant (P<0.05). The incidence of bleeding in the observation group was lower than that in the control group, and the difference was statistically significant (P<0.05). The puncture time in the observation group was shorter than that in the control group, with statistically significant difference (P<0.05). No radial artery occlusion occurred in either group. Conclusion Ultrasound-guided dual-development line localization technology can quickly and accurately determine the puncture point, shorten the puncture time, improve the success rate of the first puncture during radial artery puncture in children, and reduce the incidence of complications.
叶丽群;潘洁琼. 超声引导双显影线定位技术在小儿手术患者桡动脉穿刺置管中的应用[J]. 中国当代医药, 2021, 28(19): 137-140.
YE Li-qun PAN Jie-qiong. Application of ultrasound-guided double development line localization technique in radial artery puncture and catheterization in pediatric surgery patients. 中国当代医药, 2021, 28(19): 137-140.
Sen S,Ge M,Prabhakar A,et al.Recent technological advancements in regional anesthesia[J].Best Pract Res Clin Anaesthesiol,2019,33(4):499-505.
[8]
Hui DS,Chow BK,Lo T,et al.Exhaled air dispersion during high-flow nasal cannula therapy versus CPAP via different masks[J].Eur Respir J,2019,53(4):1802339.