Analysis on the effect of disinfection and sterilization in medical institutions in Xigang District of Dalian City during 2012-2016 |
MA Yun-qiang ZHAN Yang |
Xigang District Center for Disease Control and Prevention of Dalian City in Liaoning Province,Dalian 116011,China |
|
|
Abstract ObjectiveTo understand the disinfection and sterilization effect of monitoring medical institutions at all levels in Xigang district,so as to improve the quality of medical institutions,prevent and control nosocomial infection.MethodsStatistical methods was used to analyze the data of monitoring results of medical institutions at different levels in Xigang district from January 2012 to April 2016.ResultsFrom January 2012 to April 2016,a total of 1638 samples were dectected,the total qualified rate of all samples was 94.6%.Qualified rate of 2012,2013,2014,2015,2016 was 91.5%,98.8%,99.5%,95.7%,91.3%respectively (P<0.05).Qualified rates of medical staff hands,air,object surface,pressure sterilizer,sterile packet detection,sewage,disinfectants and disinfection of endoscope was 89.9%,94.9%,99.3%,96.0%, 93.2%,88.6%,100.0%,100.0%,the difference in qualified rate of the medical staff hands,air,sterile packet detection and sewage each year was statistically significant(P<0.05),qualified rate of object surface,pressure sterilizer,disinfectants and disinfection of endoscopes in each year was compared,the difference was not statistically significant(P>0.05).Qualified rate in three hospitals at different levels of medical institutions was up to 92.3%,the lowest qualified rate of 31.2%in dental institutions,the monitoring unit qualified rate from high to low was respectively first-level hospital,second-class hospital and other medical units(except dental medical institution),the difference in qualified rate at different levels of monitoring unit detection was statistically significant(χ2=29.934,P<0.05).ConclusionDisinfection and sterilization effect of medical institutions at all levels is good,but there are still potential danger of nosocomial infection,disinfection monitoring should be further strengthened,especially to the monitor of hand hygiene and sewage.
|
|
|
|
|
[1] |
冯丽梅,罗世武.2009-2012年广州市白云区医疗机构消毒监测结果分析[J].热带医学杂志,2013,13(3):374-375.
|
[2] |
周淑萍,许晨耘,柯雅娟,等.海南省口腔器械清洗消毒现状调查分析[J].重庆医学,2014,43(10):1231-1233.
|
[3] |
GB15982-2012.医院消毒卫生标准[S].2012.
|
[4] |
钟艳,方英,刘育兰,等.2015年株州市医疗机构消毒灭菌效果监测[J].河南预防医学杂志,2016,27(10):791-792.
|
[5] |
谭学筠,李大兴,肖伦,等.2010-2012年重庆市九龙医疗机构消毒效果监测[J].预防医学情报杂志,2014,30(6):460-463.
|
[6] |
李峰,陈胤忠,殷俊.盐城市区医疗机构消毒质量监测结果[J].中国消毒学杂志,2015,32(3):242-243.
|
[7] |
徐丹,陈玉凤,董毅.2009-2012年大连市医疗机构消毒灭菌效果监测[J].中国消毒学杂志,2015,32(1):69-70.
|
[8] |
苗晓红.2012-2014年绥芬河市牙科诊所消毒效果监测结果分析[J].中国卫生产业,2015,12(6):19-20.
|
[9] |
李英.内蒙古鄂尔多斯某区托幼机构消毒质量监测结果[J].中国消毒杂志,2014,31(10):1127-1128.
|
[10] |
郭永吉.2014年山西省岚县医疗机构消毒效果监测结果分析[J].实用医技杂志,2014,21(10):1085-1086.
|
[11] |
曹沛沛,张彦宁,高丽,等.2012-2013年大连市医疗机构消毒质量监测[J].预防医学论坛,2014,20(12):926-927.
|
[12] |
陈玉凤,徐丹,侯君,等.2009-2013年大连市医疗机构消毒灭菌效果监测分析[J].中国卫生工程学,2015,14(3):251-253.
|
[13] |
张焯俊,古国平,郑少敏,等.2011-2013年东莞市厚街镇医疗机构消毒质量检测结果分析[J].医疗动物防制,2015,31(3):292-294.
|
[14] |
姜健康,闫青芳,肖亮.2009-2012年聊城市市辖医疗机构消毒监测效果[J].预防医学论坛,2014,20(1):45-46.
|
[15] |
王会平,张洪江,王仲华.北京某城区医疗机构消毒效果调查[J].中国消毒学杂志,2014,31(2):157-159.
|
|
|
|