Improvement of digestive endoscope disinfection method and its effect observation |
ZHANG Ting1 LUO Zu-mei1 LIU Hai-yan2 ZHANG Guo-an2 GAN Mei-chan3 HUANG Miao-ying1 |
1.Digestive Endoscopy Room,People′s Hospital of Jiangmen City,Guangdong Province,Jiangmen 529000,China;2.Department of Gastroenterology,People′s Hospital of Jiangmen City,Guangdong Province,Jiangmen 529000,China;3.Department of Pharmaceutical Inspection,People′s Hospital of Jiangmen City,Guangdong Province,Jiangmen 529000,China |
|
|
Abstract ObjectiveTo investigate the effect of improved cleaning and disinfection methods.MethodsA total of 210 digestive endoscopes that were routinely cleaned and disinfected from May 2016 to October 2017 in our hospital were selected as the control group,210 digestive endoscopes with improved cleaning and disinfection methods were selected as the observation group.The qualified rate of endoscopic disinfection between the two groups was compared.ResultsThere was no significant difference between the two groups in the effect of endoscopic disinfection for one minute (P>0.05).The effect of disinfection in the observation group for three minutes and five minutes was better than that in the control group respectively and the differences were statistically significant(P<0.05).The qualified rate of the lens body and the bending part of the observation group were higher than those of the control group(P<0.05).There was no statistical difference in the passing rate of the biopsy hole between the two groups (P>0.05).There was no significant difference in patients between the two groups for the incidence of gastrointestinal discomfort or chemical colitis after microscopic examination (P>0.05).The incidence of adverse reactions caused by o-phthalaldehyde in the observation group was lower than that of the control group(glutaraldehyde),and the difference was statistically significant(P<0.05).ConclusionAfter the disinfection method of digestive endoscope is improved,the use of o-phthalaldehyde for disinfection has a significant effect,and it can greatly improve the qualified rate of cleaning and disinfecting the endoscope,effectively avoid the secondary pollution of endoscope,and the iatrogenicity caused by digestive endoscopy.Infection has a good preventive effect and it has a good preventive effect on iatrogenic infection caused by digestive endoscopy.
|
|
|
|
|
[1] |
孟庆贺.消化内镜消毒方法及消毒剂研究进展[J].河南预防医学杂志,2016,27(11):828-830.
|
[2] |
朱春梅,姜爱萍,薛祥龙.消化内镜清洗消毒中存在问题及对策[J].护理实践与研究,2017,14(19):110-112.
|
[3] |
张丽华,陈秀荣,尹晓华,等.消化内镜医院感染相关因素及不同清洗消毒方法对灭菌效果的影响[J].中华医院感染学杂志,2017,27(24):5715-5718.
|
[4] |
胡银清,帅红梅,刘晓利.消化内镜消毒灭菌效果的影响因素分析与质量管理[J].护理实践与研究,2015,12(12):7-9.
|
[5] |
雷碧霞,谭建兰,杨滢,等.影响消化内镜消毒灭菌效果相关因素分析及质量管理[J].中国实用医药,2017,12(10):195-197.
|
[6] |
符成峰,郑德权,曾雄,等.胃镜采用戊二醛和邻苯二甲醛消毒的效果比较[J].现代消化及介入诊疗,2016,21(4):630-632.
|
[7] |
荣秋华,张莹.消化内镜清洗消毒过程中存在的问题与对策[J].中华医院感染学杂志,2012,22(16):3597-3599.
|
[8] |
卢凌,姜茗,张强,等.一种复方邻苯二甲醛消毒液杀菌效果的实验观察[J].中国消毒学杂志,2015,32(9):865-866,870.
|
[9] |
周好杨,任晓敏,张殷雷,等.消化内镜清洗消毒流程优化在消化科感染防控中的应用研究[J].检验医学与临床,2016,13(15):2151-2152.
|
[10] |
赵淑云.腔镜手术器械消毒灭菌方法的改进与效果观察[J].中西医结合心血管病电子杂志,2016,4(31):182-183.
|
[11] |
傅玉仙.手术室内镜器械的清洗消毒方法研究[J].中国消毒学杂志,2016,33(1):36-38.
|
[12] |
周武坚,钱小婷,许娇.消化内镜消毒灭菌效果的影响因素分析与质量管理探究[J].临床研究,2017,25(5):9-10.
|
[13] |
朱剑.消化内镜消毒灭菌效果的影响因素分析及质量控制[J].中西医结合护理(中英文),2017,3(9):171-173.
|
[14] |
郑璟琳.消化内镜清洗消毒流程优化在消化科感染防控中的应用研究[J].饮食保健,2016,3(24):20.
|
[15] |
付艳.浅析消化内镜清洗消毒的优化管理[J].中国医疗器械信息,2017,23(12):110-111.
|
[16] |
曹艳,杨莹莹,韩然,等.消化内镜清洗及消毒质量监测不合格原因分析及干预措施探讨[J].重庆医学,2017,46(1):111-113.
|
|
|
|