The effect of cryoprecipitation dissolution with dry blood soluble machine and water-bath blood soluble machine and the length of dissolution time on the biological activity of coagulation factor in cryoprecipitate |
YANG Qing-wen, LI Guang-ying, DING Wen |
Baoan District Hospital of Traditional Chinese Medicine (Group),Guangdong Province,Shenzhen 518133,China |
|
|
Abstract Objective To investigate the use of dry and water-bath blood soluble machine for cryoprecipitation dissolution and the effect of length of dissolution time on the biological activity of coagulation factors in cryoprecipitate,in order to provide the basis for better results.Methods Altogether 120 bags of cryoprecipitate (Specification:1.0 U/Bag) with similar blood collection dates (less than 5 days) that were provided by our Central Blood Station of Baoan from February 3rd to February 7th in 2016 were selected and randomly divided into two groups (group 1 and group 2),with 60 bags in each group.group 1 adopted dry blood soluble machine for cryoprecipitation dissolution;while,group 2 adopted water-bath blood soluble machine for cryoprecipitation dissolution.FactorⅧ (FⅧ),von Willebrand factor antigen (vWF-Ag),prothrombin time (PT),thrombin time (TT),activated partial thromboplastin time (APTT) and plasma fibrinogen (Fib) of 120 cryoprecipitate samples that were placed in different blood soluble machines at 37℃ for 10,20 min and 30 min were determined.Results There was no statistically significant difference between group 1 and group 2 in the effects of blood plasma dissolution and all the indexes (P>0.05);however,with the prolonging of dissolution time,prolonged APTT as well as decreased activity of FⅧ and VWF antigen were seen,with statistically significant difference (P<0.05).Conclusion Prolonged blood plasma dissolution time will lead to decreased activity of FⅧ and VWF antigen as well as prolonged APTT,with statistically significant difference.To achieve better efficacy of clinical blood transfusion,the best time for cryoprecipitation dissolution is recommended to be 10 min.
|
Received: 15 June 2017
|
|
|
|
|
Cite this article: |
YANG Qing-wen,LI Guang-ying,DING Wen. The effect of cryoprecipitation dissolution with dry blood soluble machine and water-bath blood soluble machine and the length of dissolution time on the biological activity of coagulation factor in cryoprecipitate[J]. 中国当代医药, 2017, 24(24): 118-120.
|
|
|
|
URL: |
http://dangdaiyiyao.com/EN/ OR http://dangdaiyiyao.com/EN/Y2017/V24/I24/118 |
[1] |
梁其隆,梁若鹄,陈龙菊,等.冷沉淀解冻后凝血因子变化的实验研究[J].中国医药导报,2012,9(11):28-30.
|
[2] |
邹宗丽,甘芳香,车火娇,等.冷沉淀在不同温度不同时间放置对Ⅷ因子的影响[J].医学检验,2012,19(36):90-91.
|
[3] |
范红玲.单采血小板联合冷沉淀在大出血患者临床治疗中的应用[J].中国实用医刊,2012,39(7):105-106.
|
[4] |
陈善华,朱丽莉,吕红艳,等.保证临床用血的应对措施探析[J].中国输血杂志,2011,24(8):695-696.
|
[5] |
何子毅,田兆嵩.冷沉淀的临床应用[J].中国输血杂志,2008,21(12):986.
|
[6] |
Neimark AI,Gatkin ML.Use of cryoprecipitate in combined therapy of acute purulent pyelonephritis[J].Urologiia,2005, 4:42-48.
|
[7] |
刘景汉,王德清.临床输血学[M].北京:人民卫生出版社,2011:40.
|
[8] |
苏红,谭爱玲,徐少英,等.冷沉淀制备的关键控制环节[J].中国医学创新,2012,10(10):144-145.
|
[9] |
万鹏,童华生,张兴钦,等.新型凝血和血小板功能分析仪在弥散性血管内凝血早期诊断中的价值[J].中国急救医学,2014,10(9):789-793.
|
[10] |
胡豫.2012版弥散性血管内凝血诊断与治疗中国专家共识解读[J].临床血液学杂志,2013,2(11):978-979.
|
[11] |
Ettinger A,Miklauz MM,Bihm DJ, et al .Preparation of cryoprecipitate from riboflavin and UV light-treated plasma[J].Transfus Apher Sci,2012,6(46):153-158.
|
[12] |
Funk MB,Heiden M,Volkers P, et al .Evaluation of risk min-imisation measures for blood components-based on reporting rates of transfusion-transmitted reactions (1997-2013)[J].Transfus Med Hemother,2015,42(4):240-246.
|
[13] |
陈志军,吴稷,樊琴红,等.冷沉淀制备技术在血液成分制备中的应用[J].中国中医药咨讯,2011,3(11):69-70.
|
[14] |
Bui E,Inaba K,Ebadat A, et al .The impact of increased plasmaratios in massively transfused trauma patients:a prospective analysis[J].Eur J Trauma Emerg Surg,2016,42(4):519-525.
|
[15] |
Shaz BH,Stowell SR,Hillyer CD.Transfusion-related acute lung injury:from bedside to bench and back[J].Blood,2011, 117(5):1463-1471.
|
|
|
|