Application effect of Dacronin Hydrochloride Mucilage in colonoscopy |
HU Jun FAN Yan-jun▲ LI Zhi-jin HUANG Xiao-mei |
Department of Digestion, the 908th Hospital of PLA Joint Logistic Support Force, Jiangxi Province, Yingtan 335000,China |
|
|
Abstract Objective To observe the application effect of oral different doses of Dacronin Hydrochloride Mucilage in colonoscopy.Methods From July 1 to December 31, 2018, 843 patients who underwent colonoscopy in the digestive department of our hospital were randomly divided into high dose group (288 cases), low dose group (281 cases) and control group (274 cases).All the patients in each group were prepared with Polyethylene Glycol before operation.A total of 40 ml and 100 ml warm water were given to the high dose group 1 hour before enteroscopy, and 20 ml and 100 ml warm water were given to the low dose group.The control group did not take Dacronin Hydrochloride Mucilage, did not take any measures.The colonoscopy was performed by the same senior endoscopic surgeon to evaluate the grade of intestinal foam and the score of intestinal cleanliness, and the colonoscopy time, operation time and polyp detection rate of the three groups were recorded and compared.Results The foam quantity grade of the high dose group and the low dose group were better than that of the control group, and the differences were statistically significant (P<0.05).The grade of intestinal foam volume in the high-dose group was better than that in the low-dose group, and the difference was statistically significant (P<0.05).The Boston bowel preparation scale (BBPS) scores of the high dose group, the low dose group and the control group were (7.84±0.97), (7.96±1.04) and (7.88±1.09) points, respectively.There were no significant differences in BBPS scores among the three groups (P >0.05).There was no significant difference in colonoscopy time in the three groups (P>0.05).The colonoscopy time of the high dose group and the low dose group was shorter than that of the control group, and the differences were statistically significant (P<0.05).The colonoscopy time of the high dose group was shorter than that of the low dose group, and the difference was statistically significant(P<0.05).The detection rate of total polyps and micropolyps in the high dose group was not significantly different from that in the low dose group (P>0.05).No serious adverse reactions such as dizziness, headache, chest tightness, palpitations and drug allergy occurred in the high dose group and the low dose group.Among all the patients, 11 patients experienced nausea, vomiting, abdominal distension and other discomfort during intestinal preparation, including 3 patients in the high dose group, 5 patients in the low dose group and 3 patients in the control group, which were considered to be related to the preparation of taking a large amount of water into the intestinal tract in a short period of time, but not related to the oral administration of dacronin hydrochloride pulp and glue.Conclusion Dacronin Hydrochloride Mucilage can effectively remove intestinal foam and improve the detection rate of intestinal polyps and micropolyps, and the effect of oral 40 ml Dacronin Hydrochloride Mucilage in removing intestinal foam is better than that of 20 ml.
|
|
|
|
|
[1] |
Kim HG,Huh KC,Koo HS,et al.Sodium Picosulfate with Magnesium Citrate(SPMC)plus laxative is a good alternative to conventional large volume polyethylene glycol in bowel preparation: a multicenter randomized single-blinded trial[J].Gut Liver,2015,9(4):494-501.
|
[3] |
高燕,张厚德,林木贤,等.Boston 肠道准备量表应用的信度评估[J].中华消化内镜杂志,2012,29(2):78-80.
|
[7] |
张秋生,彭侠彪,崔惠敏,等.青年人大肠癌临床、内镜、病理特点分析[J].中华消化内镜杂志,2004,21(5):349-351
|
[8] |
安祯祥,王敏,蹇忠禄.盐酸达克罗宁胶浆与盐酸利多卡因胶浆复合静脉麻醉在胃镜检查中的对比研究[J].贵州医药,2016,40(3):280-281.
|
[2] |
Lai EJ,Calderwood AH,Doros G,et al.The Boston bowel preparation scale:a valid and reliable instrument for colonoscopy-oriented research[J].Gastrointest Endosc,2009,69(3Pt2):620-625.
|
[4] |
Gralnek IM,Carr-Locke DL,Segol O,et al.Comparison of standard forward-viewing mode versus ultrawide-viewing mode of a novel colonscopy platform:a prospective,multicenter study in the detection of simulated polyps in an in vitro colon model(with video)[J].Gastrointest Endosc,2013,77(3):472-479.
|
[5] |
Wu L,Cao Y,Liao C,et al.Systematic review and metaanalysis of randomized controlled trials of Simethicone for gastrointestinal endoscopic visibility [J].Scand J Gastroenterol,2011,46(2):227-235.
|
[6] |
Voiosu T,Voiosu A,Voiosu R.Bowel preparation for colonoscopy:state of the art[J].Curr Opin Gastroenterol,2016,32(5):385-386.
|
[9] |
程勇卫,林燕鸿,周少明.盐酸达克罗宁胶浆在儿童胃镜检查中的临床观察[J].中国当代医药,2016,23(20):105-107.
|
[10] |
许田英,孙占埠.比较盐酸达克罗宁胶浆与盐酸奥布卡因凝胶在胃镜检查中的应用效果[J].系统医学,2018,3(16):55-57.
|
[11] |
梁慧敏,吴中飞,卜冬云.盐酸达克罗宁胶浆两种服用方法在电子鼻咽喉镜检查中的麻醉效果比较[J].中国中西医结合耳鼻咽喉科杂志,2018,26(4):312-314.
|
[12] |
姚宇亮.达克罗宁胶浆局部喷洒在内镜下结肠息肉电切术中的应用[J].四川医学,2015,4(36):536-538.
|
[13] |
黄子丹,莫玉娇,陀健琳,等.达克罗宁胶浆在前列腺增生患者导尿术中的应用[J].中华现代护理杂志,2018,24(10):1191-1194.
|
[14] |
王远志,严志刚,丁岩冰,等.术中喷洒盐酸达克罗宁胶浆在结肠镜检查中祛泡效果的研究[J].中华消化内镜杂志,2016,33(9):639-641.
|
[15] |
娄青玲,高峰.盐酸达克罗宁胶浆在肠镜检查中去泡效果的单中心随机对照研究[J].中华消化内镜杂志,2017,34(8):582-585.
|
|
|
|