|
|
Application effect of compound neutralization eluent in monitoring microorganism on high frequency contact surface in surgical ward under novel coronavirus pneumonia outbreak situation |
LU Jing XU Bao-hua HUANG Yan-xiang |
Department of Infection Management,the Third Affiliated Hospital of Gannan Medical College,Jiangxi Province,Ganzhou 341000,China |
|
|
Abstract Objective To investigate application effect of compound neutralization eluent in monitoring microorganism on high frequency contact surface in surgical ward under novel coronavirus pneumonia(COVID-19)outbreak situation.Methods A total of 300 microbiological specimens were selected from the high-frequency contact tables(dressing room table,door handle,computer keyboard,elevator keys and landline telephone)in the surgical ward of the Third Affiliated Hospital of Gannan Medical College from June to November 2020,and divided into observation group(n=150)and control group(n=150)according to the type of eluent.Compound neutralization eluent was used in the observation group and normal saline eluent was used in the control group.The over-standard rate of total number of colonies and the satisfaction of the staff to the effect of eluent were compared between the two groups.Results The over-standard rate of total contact surface colonies in observation group was 20.0%,which was higher than that in control group(8.0%),the difference was statistically significant(P<0.05).The satisfaction rate of the observation group was 93.3%,which was higher than that of the control group(66.7%),the difference was statistically significant(P<0.05).Conclusion In the context of COVID-19 epidemic,the application effect of compound neutralization eluent in the monitoring of high-frequency contact surface microorganisms in surgical ward was better than that of conventional saline eluent,which could improve the detection rate of microorganisms exceeding the standard and facilitate the culture of residual microorganisms after disinfection.
|
|
|
|
|
Cite this article: |
LU Jing,XU Bao-hua,HUANG Yan-xiang. Application effect of compound neutralization eluent in monitoring microorganism on high frequency contact surface in surgical ward under novel coronavirus pneumonia outbreak situation[J]. 中国当代医药, 2021, 28(15): 192-194.
|
|
|
|
URL: |
http://dangdaiyiyao.com/EN/ OR http://dangdaiyiyao.com/EN/Y2021/V28/I15/192 |
[1] |
范锦辉,周毓瑾,梁朝晖,等.民用航空器客舱物表微生物污染现状调查研究[J].民航医学,2019,29(3):160-164.
|
[2] |
胡国庆,段亚波.GB15982-2012《医院消毒卫生标准》内容解读(一)[J].中国消毒学杂志,2013,30(7):649-652.
|
[3] |
乔甫,黄文治,宗志勇.多重耐药菌感染防控的意义与发展趋势[J].中国护理管理,2019,19(8):1129-1134.
|
[4] |
宛传丹,周金保,邹学军,等.ICU环境细菌学监测结果与医院感染病原菌耐药谱同源性分析[J].现代预防医学,2016,43(17):3235-3240.
|
[5] |
刘燕辉,蔡亚军,吴图扬,等.移动通讯工具物表微生物携带状况及消毒效果评价[J].中国病原生物学杂志,2013,8(11):1023-1024,1028.
|
[6] |
刘虹,王航,汪雪格,等.一株既产表面活性剂又高效降解石油烃菌株的鉴定及降解效果[J].生态环境学报,2015,24(12):2035-2039.
|
[7] |
陆喜颜,刘美真,陈经雕,等.12种抗菌药物对广东省不同血清群脑膜炎奈瑟菌敏感性分析[J].华南预防医学,2013,39(3):49-52.
|
[8] |
杨竹兰,张波,吴昊,等.神经外科ICU终末消毒效果监测[J].国际检验医学杂志,2013,34(24):3274-3276.
|
[9] |
李瑞锋.某院临床微生物检验及其耐药性监测结果对合理用药的影响[J].抗感染药学,2020,17(3):360-362.
|
[10] |
潘书正,张明明,王东政.2017年三门峡市某区公共场所卫生监测微生物检测结果分析[J].应用预防医学,2020,26(1):77-78.
|
[11] |
欧木生.公共场所空气微生物监测结果分析[J].基层医学论坛,2020,24(11):1587-1588.
|
[12] |
常力川.微生物检验及细菌耐药性的监测结果分析[J].中国医药指南,2020,18(1):64.
|
[13] |
阮雁春.肉制品微生物检测中金黄色葡萄球菌监测数据分析[J].食 品安全 质 量检 测学报,2020,11(21):8041-8046.
|
[14] |
叶石兴,徐伟兵.2015年惠州市某区公共场所卫生监测微生物项目检测结果分析[J].中国当代医药,2018,25(12):158-160.
|
[15] |
樊其柱,林丽君,吴婷,等.预防手开放损伤感染的微生物检查与治疗[J].中国当代医药,2017,24(3):64-67.
|
|
|
|