Application of modified Y-type disposable venous blood sampling needle in clinical blood sampling |
CHEN Xue-qin1 TANG Wen2 PAN Yan-juan3 |
1.Department of Orthopedics, Jiujiang First People′s Hospital, Jiangxi Province, Jiujiang 332000, China;
2.Department of Otorhinolaryngology, Head and Neck Surgery, Jiujiang First People′s Hospital, Jiangxi Province, Jiujiang 332000, China;
3.Department of Pain, Jiujiang First People′s Hospital, Jiangxi Province, Jiujiang 332000, China |
|
|
Abstract Objective To explore the application effect of modified Y-type disposable venous blood collection needle in clinical blood collection.Methods A total of 200 patients admitted to Jiujiang First People′s Hospital Jiangxi Province from November 2019 to June 2020 were selected as the research objects, and they were divided into two groups according to the lottery method, 100 cases in each group.The control group used a disposable venous blood collection needle to collect blood, and the observation group used a modified Y-type disposable venous blood collection needle to collect blood.The success rate, blood contamination rate, blood sample qualification rate and satisfaction degree of the two groups were compared.Results The success rates of one-time blood collection from the dorsal hand vein, the median cubital vein, and the vein in the observation group were (98.00%, 99.00%, 96.00%), which were higher than those of the control group of (91.00%, 92.00%, 88.00%), and the differences were statistically significant (P<0.05);the blood contamination rate of the observation group was 2.00%, lower than that of the control group for 9.00%, and the qualified rate of blood samples was 98.00%, higher than that of the control group 91.00%, the differences were statistically significant (P<0.05).The total satisfaction rate of blood sampling was 98.00%, higher than that of the control group for 90.00%, the difference was statistically significant (P<0.05).Conclusion The use of modified Y-type disposable venous blood sampling needle for blood sampling can reduce the blood contamination rate, improve the success rate of blood sampling, the qualified rate of blood samples and blood sampling satisfaction.
|
|
|
|
|
[1] |
陈艳,陈峻,王媛媛.一次性采血针与注射器应用于颈外静脉留置针穿刺的效果[J].血栓与止血学,2017,23(1):128,130.
|
[2] |
丁冬霞.真空静脉采血常见的失败原因分析及护理措施探讨[J].实用临床医药杂志,2017,21(10):163-165.
|
[3] |
阿尤甫·牙生,玛依拉·热合曼.不同采血方法进行血常规检验在临床应用中的价值分析[J].临床检验杂志(电子版),2018,7(2):244-245.
|
[4] |
曹秋君,吴燕.静脉采血最佳证据传播及应用现状调查[J].中国实用护理杂志,2018,34(19):1441-1445.
|
[5] |
万敏,姚秀军,施燕平,等.一次性使用静脉采血针刺穿力的研究[J].中国医疗设备,2018,33(11):19-22.
|
[6] |
黄姗剑,骆婷,张琴,等.真空采血管在临床使用中所致不良事件的原因分析[J].东南国防医药,2018,20(6):97-99.
|
[7] |
汪怀周,方雯,陈明坤,等.真空采血管采血量对常用临床生化检验项目结果的影响[J].检验医学,2017,32(2):94-98.
|
[8] |
杜作江.末梢血和静脉血不同采血方法进行血常规检验在临床中的比较[J].临床检验杂志(电子版),2018,7(3):472-473.
|
[9] |
徐源,修皓,裴华,等.新型静脉采血器与头皮针式采血针结构对比研究及使用效果评价[J].检验医学与临床,2019,16(24):3582-3584.
|
[10] |
何德化,林开敏,张紫冠,等.经肘正中静脉分侧肾上腺静脉采血术操作流程改良的效果[J].中华高血压杂志,2020,28(6):539-543.
|
[11] |
陈金明,吴月娜,赵新瑶.改良注射按压贴在门诊静脉采血病人中的应用研究[J].黑龙江中医药,2020,49(2):345-346.
|
[12] |
姜春英,张华秀,徐亮,等.快速小角度直刺法改良采血技术对采血标本质量的影响[J].中国当代医药,2020,27(5):197-199,209.
|
[13] |
王翠梅.快速小角度直刺针法对受检者采血疼痛的探究[J].实用临床护理学电子杂志,2019,4(45):182-183.
|
[14] |
陈宇玲,吴丽真.小儿股静脉采血改良方法的应用效果[J].福建医药杂志,2017,39(1):176-177.
|
[15] |
彭惠兰.改良新生儿股静脉穿刺采血方法的应用分析[J].安徽卫生职业技术学院学报,2016,15(5):166-167.
|
|
|
|