|
|
Effect of blood glucose on first implantation pacing parameters of patients undergoing permanent pacemaker implantation |
MO Hai-liang WU Zi-jun HUANG Rui-na CHEN Lu-jun SUN Qi-fan WU Keng▲ |
The First Department of Cardiology,the Affiliated Hospital of Guangdong Medical University,Zhanjiang 525000,China |
|
|
Abstract Objective To investigate the effect of blood glucose on first implantation pacing parameters of patients undergoing permanent pacemaker implantation.Methods A total of 231 patients undergoing permanent pacemaker implantation treated in the hospital from March 2014 to March 2019 were selected as the subjects,and retrospective analysis was conducted.According to the blood glucose,they were divided into group A(patients with diabetes,42 cases),group B(patients with impaired glucose tolerance,118 cases)and group C(patients with normal blood glucose,71 cases).The pacing threshold,perception,impedance,program-controlled test time of pacemaker parameters were compared among the three groups.The correlation between blood glucose and pacing parameterswas analyzed.Results The ventricular pacing threshold,perception,impedance in group A and group B were higher than those in group C,and the program-controlled test time of parameters was longer than that in group C,and the differences were statistically significant(P<0.05).There was no statistically significant difference in ventricular pacing threshold,perception or impedance between the group A and group B(P>0.05).The ventricular parameter programmable test time in group A was longer than that of group B,the difference was statistically significant(P<0.05).The levels of fasting blood glucose(FBG)and blood glucose 2 hours aftermeal(2 h BG)in group A and group B were higher than those in group C,and the FBG and 2 h BG levels of group A were higher than those of group B,the differences were statistically significant(P<0.05).Spearman correlation analysis showed that FBG was positively correlated with pacing threshold,perception,impedance and program-controlled test time of parameters(r=0.410,0.352,0.332,0.318;P<0.05).And 2 h BG was positively correlated with the pacing threshold,perception,impedance and program-controlled test time of parameters(r=0.425,0.367,0.346,0.327;P<0.05).Conclusion Blood glucose has influence on the pacing threshold,impedance and perception of patients undergoing pacemaker implantation.High blood glucose will lead to elevated pacing threshold and impedance,decreased sensitivity and prolongation of program-controlled test time of parameters.
|
|
|
|
|
[1] |
孙苗,王军奎,姬新才,等.2型糖尿病患者抑郁评分与左室射血分数的相关性研究[J].临床内科杂志,2018,35(2):127-128.
|
[2] |
Li G,Zhang P,Wang J,et al.Cardiovascular mortality,allcausemortality,and diabetes incidence after lifestyle intervention for people with impaired glucose tolerance in the Da Qing Diabetes Prevention Study:a 23-year follow-up study[J].Lancet Diabetes Endocrinol,2014,2(6):474-480.
|
[3] |
常沁涛.糖尿病肾病患者心血管疾病患病率及其危险因素分析[J].中国药物与临床,2017,17(11):1606-1608.
|
[4] |
成玲,张哲林,孟根托娅,等.2型糖尿病患者血糖波动与心律失常的相关性分析[J].现代生物医学进展,2016,16(24):4672-4675.
|
[5] |
王芝荣,舒娟,吴利杰.心律失常患者永久起搏器植入术后房颤、脑卒中发生情况及相关危险因素分析[J].医学临床研究,2018,35(9):1768-1770.
|
[6] |
余阳,杨洪涛,卢清玉.心脏起搏器预防和终止慢性心律失常的疗效及对心功能的影响[J].实用临床医药杂志,2018,22(1):21-23.
|
[7] |
李日健,黄瑞娜,吴铿,等.永久性心脏起搏器植入术后起搏阈值升高患者的临床特点及其相关影响因素分析[J].临床医学工程,2016,23(2):187-188.
|
[8] |
乔青,徐伟.ACCF/AHA/HRS植入器械指南中普通起搏器植入适应证解读[J].中国介入心脏病学杂志,2014,22(9):611-612.
|
[9] |
张燕峰.糖尿病患者糖化血红蛋白与心律失常的相关性研究[J].中国循证心血管医学杂志,2018,10(11):133-134,137.
|
[10] |
顾楠,张俊清,郭晓蕙.动态葡萄糖图谱在糖尿病患者中的应用[J].中华糖尿病杂志,2018,10(11):753-756.
|
[11] |
杨红霞,米树华,苏工,等.血糖波动对急性心肌梗死患者左心功能的影响研究[J].中国全科医学,2017,20(10):1181-1185.
|
[12] |
吴铿,游琼,郑锡锋,等.糖尿病对永久人工心脏起搏器术起搏参数及并发症的影响[J].心血管康复医学杂志,2014,23(2):188-190.
|
[13] |
白慧华,周铸,邓楠.2型糖尿病患者发生血管并发症的危险因素分析[J].海南医学,2018,29(13):1802-1804.
|
[14] |
陈超,柯剑娟,丁煌,等.糖尿病因素对腺苷后处理减轻大鼠心肌缺血再灌注损伤的影响[J].中华麻醉学杂志,2018,38(3):292-295.
|
[15] |
杨艳,马艳,林丽霞,等.永久性心脏起搏器置入术后起搏阈值升高患者的临床特点及其相关影响因素分析[J].临床和实验医学杂志,2018,17(10):84-87.
|
[16] |
曹田田,曹艳丽.血糖波动致内皮细胞损伤机制及绿茶对内皮细胞的保护作用[J].医学综述,2016,22(20):4046-4050.
|
|
|
|