Application value of dual-energy spectrum CT in head and neck CT angiography in eliminating artifacts of vascular metal implants |
TAO Na YAN Fei-hu ZHENG Wei GONG Tao CHEN Long-feng WANG Ying-hua |
Department of Radiology,Yichun People′s Hospital of Jiangxi |
|
|
Abstract Objective To analyze the application value of dual-energy spectrum CT in head and neck CT angiography in eliminating artifacts of vascular metal implants.Methods From April 2019 to April 2020,a total of 30 patients with CTA reexamination after head and neck vascular metal implants Yichun People′s Hospital were selected and divided into the control group and the experimental group,15 cases in each group.The control group was given 120 keV conventional CTA images,while the experimental group was reconstructed with 60-100 keV single energy data every 10 keV,and there were 5 groups of single energy images.The hardening artifacts,vascular contrast and image quality were compared between the two groups.Results The artifact index of the experimental group was lower than that of the control group,while the contrast to noise ratio of the experimental group was higher than that of the control group,and the differences were statistically significant (P<0.05).When the the voltage was 70 keV in the experimental group,the artifact index was lower than the voltage was 60 keV and 100 keV,the differences were statistically significant (P<0.05).When the the voltage was 80 keV in the experimental group,the artifact index was lower than the voltage was 60 keV,90 keV and 100 keV,the differences were statistically significant (P<0.05).When the voltage was 70 and 80 keV in the experimental group,the contrast to noise ratio was higher than other voltage values,and the differences were statistically significant (P<0.05).The image quality of CT in the experimental group was higher than that in the control group,and the difference was statistically significant (P<0.05).Conclusion Dual-energy spectrum CT can effectively reduce the artifacts of vascular metal implants in head and neck CT angiography,and the effect of eliminating metal artifacts is the best at 70-80 keV.
|
|
|
|
|
[1] |
Wellenberg RHH,Donders JCE,Kloen P,et al.Exploring metal artifact reduction using dual-energy CT with pre-metal and post-metal implant cadaver comparison:are implant specific protocols needed?[J].Skeletal Radiol,2018,47(6):839-845.
|
[2] |
陈蕾蕾,陈自谦,许尚文,等.ET/CT 显像常见伪影及质量控制[J].中国医疗设备,2019,34(2):17-20,24.
|
[3] |
陈小玫,刘彪,谢兆林,等.应用Flash CT 消减脊柱金属植入物伪影的探讨[J].中国CT 和MRI 杂志,2018,16(8):138-141.
|
[4] |
高江晖,李玉芳,马洪宇,等.双源Flash CT 单能谱成像技术减少腰椎金属固定器伪影的研究[J].中国伤残医学,2016,24(11):5-7.
|
[5] |
Munaweera I,Shaikh S,Maples D,et al.Temperature-sensitive liposomal ciprofloxacin for the treatment of biofilm on infected metal implants using alternating magnetic fields[J].Int J Hyperthermia,2018,34(2):189-200.
|
[6] |
刘卓,马婧,洪楠,等.双能量CT 联合金属伪影削减算法显示微弹簧圈定位肺结节[J].中国医学影像技术,2018,34(2):302-305.
|
[7] |
林智胜,王建伟,邓婕,等.关于降低显影剂剂量消减头颈CTA硬束伪影的研究[J].中国医疗装备,2019,34(10):68-71.
|
[8] |
李腾飞,马骥,袁慧锋,等.高分辨C型臂CT 联合去金属伪影技术在颅内动脉瘤LVIS 支架辅助栓塞术中的应用[J].中华神经外科杂志,2019,35(6):541-546.
|
[9] |
吴坚,徐冶敏,韩永顺,等.CT 能谱成像技术去除眼眶金属植入物伪影的临床应用[J].组织工程与重建外科杂志,2019,15(1):17-19.
|
[10] |
刘豹,石明国,李剑,等.OMAR 迭代去伪影技术与双能量线性融合去伪影技术的对比性研究[J].中国医疗设备,2019,34(6):23-26.
|
[11] |
金文凤,韩丹,江杰,等.自适应滤波联合迭代重建在减轻下颈部CT 伪影中的应用[J].放射学实践,2019,34(7):755-759.
|
[12] |
王淑贤,万娅敏,谭红娜,等.双源CT FAST DE 技术在去除腰椎金属内固定物伪影中的价值[J].临床放射学杂志,2016,35(3):466-469.
|
[13] |
颜森森,罗敏,汪奇慧,等.单源能谱CT在消除金属内固定伪影中的应用[J].医学影像学杂志,2016,26(1):94-95,98.
|
[14] |
赵晴晴,孙小丽,李希,等.能谱CT 单能量成像结合MAR 技术降低金属植入物伪影的体模研究[J].CT 理论与应用研究,2019,28(5):529-539.
|
[15] |
杨帆,曾懿.双能量CT 虚拟单能谱成像技术在TIPS 术后支架评估中的应用[J].中国中西医结合影像学杂志,2019,17(3):266-268.
|
|
|
|