中国当代医药
   Apr. 7, 2025    Home                              中文
中国当代医药  2022, Vol. 29 Issue (28): 96-98    DOI:
Current Issue | Archive | Adv Search |
Correlation between QRS duration,real-time three-dimensional echocardiography parameters and clinical cardiac function
LI Xing LI Zhiyong LEI Liqin ZHU Wanhong
Department of ECG Function,the Second People's Hospital of Jingdezhen City,Jiangxi Province,Jingdezhen 333000,China
Download: PDF (558 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  Objective To investigate the correlation between QRS duration (QRSd),real-time three-dimensional echocardiography parameters and clinical cardiac function.Methods A total of 30 patients with left heart failure treated in the Second People's Hospital of Jingdezhen City from January to July 2021 were selected as the study group.According to the classification standard of New York Heart Association (NYHA),they were divided into the grade Ⅱgroup,the grade Ⅲgroup and the grade Ⅳgroup,with 10 cases in each grade.At the same time,30 patients with hypertensive non left heart failure were selected as the control group.QRSd and real-time three-dimensional echocardiography parameters were measured,and the correlation between each parameter and clinical cardiac function was analyzed.Results The levels of QRSd,LVEDV,LVESV in the study group were higher than those in the control group,and the level of LVEF in the study group was lower than that in the control group,the differences were statistically significant(P<0.05).The levels of QRSd,LVEDV and LVESV in the grade Ⅳgroup of NYHA were higher than those in the gradeⅢgroup of NYHA and the grade Ⅱgroup of NYHA,and the level of LVEF in the grade Ⅳgroup of NYHA was lower than that in the grade Ⅲgroup of NYHA and the grade Ⅱgroup of NYHA,the differences were statistically significant(P<0.05).The levels of QRSd,LVEDV and LVESV in the grade Ⅲgroup of NYHA were higher than those in grade Ⅱgroup of NYHA,and LVEF in the grade Ⅲgroup of NYHA was lower than those in grade Ⅱgroup of NYHA,the differences were statistically significant (P<0.05).Pearson correlation analysis showed that QRSd was positively correlated with LVEDV and LVESV (r=0.291,0.352,P<0.05),and inversely correlated with LVEF (r=-0.397,P<0.05).Conclusion QRSd,LVEDV,LVESV are abnormally increased in patients with left heart failure,which is related to cardiac function.QRSd prolongation has certain clinical value in suggesting left heart failure.
Key wordsReal-time three-dimensional echocardiography      Heart failure      Cardiac function      QRS duration      Correlation     
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Cite this article:   
URL:  
https://www.dangdaiyiyao.com/EN/     OR     https://www.dangdaiyiyao.com/EN/Y2022/V29/I28/96
Copyright © Editorial Board of 中国当代医药
Supported by:Beijing Magtech