微螺钉种植体支抗不同植入角度对口腔正畸患者牙槽骨吸收及并发症发生率的影响
彭怡 李琴 赵旭春
江西省萍乡市人民医院口腔科,江西萍乡 337000
Effect of different implantation angles of microscrew implant anchorage on alveolar resorption and the incidence of complications in orthodontic patients
PENG Yi LI Qin ZHAO Xuchun
Department of Stomatology,Pingxiang People's Hospital,Jiangxi Province,Pingxiang 337000,China
全文: PDF (505 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 目的 探究微螺钉种植体支抗不同植入角度对口腔正畸患者牙槽骨吸收及并发症发生率的影响。方法 选取2019 年1 月至2021 年12 月萍乡市人民医院口腔科收治的需内收前牙的80 例正畸患者作为研究对象,根据微螺钉种植体支抗植入角度分为A 组(与牙槽骨骨面成30°,26 例)、B 组(与牙槽骨骨面成60°,29 例)和C 组(与牙槽骨骨面成90°,25 例)。比较两组微螺钉种植体稳定性、牙槽骨吸收情况及并发症发生率。结果 施加150 g 载力后,B 组微螺钉种植体松动率低于A 组、C 组,差异有统计学意义(P<0.017)。B 组牙槽骨高度与宽度吸收值均低于A 组、C 组,差异有统计学意义(P<0.05)。治疗期间,三组患者并发症总发生率比较,差异无统计学意义(P>0.05)。结论 微螺钉种植体以与牙槽骨骨面成60°角度植入的稳定性最佳,能更好地减少牙槽骨横向及纵向吸收,同时不会增加并发症发生率,临床医师可考虑以该角度植入微螺钉种植体。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
关键词 微螺钉种植体支抗植入角度口腔正畸牙槽骨吸收并发症    
Abstract:Objective To investigate the effect of different implantation angles of microscrew implant anchorage on alveolar resorption and the incidence of complications in orthodontic patients.Methods A total of 80 orthodontic patients who needed to be treated with retraction of anterior teeth and admitted to the Department of Stomatology at Pingxiang People's Hospital from January 2019 to December 2021 were selected as the study objects.They were divided into group A (at 30° to the alveolar surface,26 cases),group B (at 60° to the alveolar surface,29 cases)and group C(at 90°to the alveolar surface,25 cases)according to the implantation angle of microscrew implant anchorage.The stability of microscrew implant,alveolar resorptionand the incidence of complications were compared between the two groups.Results After applying 150 g of load,the microscrew implant loosening ratein of group B was lower than those in group A and group C,and the difference was statistically significant (P<0.017).The absorption values of alveolar height and width in group B were lower than those in group A and group C,and the differences were statistically significant(P<0.05).There was no statistically significant difference in the total incidence of complications among the groups(P>0.05).Conclusion The stability of microscrew implanted at an angle of 60°to the alveolar surface is the best.This method can better reduce lateral and longitudinal alveolar resorption,without increasing the incidence of complications.Clinicians can consider this angle when implanting microscrew implant.
Key wordsMicroscrew implant anchorage    Implantation angle    Orthodontics    Alveolar resorption    Complication
    
基金资助:江西省卫生健康委科技计划项目(202212168)。
通讯作者: 李琴(1977-),女,江西萍乡人,副主任医师;研究方向:口腔正畸。   
作者简介: 彭怡(1989-),女,江西萍乡人,硕士;研究方向:口腔正畸。
引用本文:   
彭怡; 李琴; 赵旭春. 微螺钉种植体支抗不同植入角度对口腔正畸患者牙槽骨吸收及并发症发生率的影响[J]. 中国当代医药, 2024, 31(11): 51-54.
PENG Yi LI Qin ZHAO Xuchun. Effect of different implantation angles of microscrew implant anchorage on alveolar resorption and the incidence of complications in orthodontic patients. 中国当代医药, 2024, 31(11): 51-54.
链接本文:  
https://www.dangdaiyiyao.com/CN/     或     https://www.dangdaiyiyao.com/CN/Y2024/V31/I11/51
中华人民共和国互联网药品信息服务资格证书(京)-非经营性-2016-0092
京ICP备11001767号-6  京公网安备 11010502046607号  互联网药品信息服务资格证  期刊出版许可证  广告经营许可证
信息产业部备案管理系统网址 http://beian.miit.gov.cn/state/outPortal/loginPortal.action
投稿热线:010-59626690 总机:010-59626692/18/19/20   传真:010-59626204   投稿信箱:ddyy@vip.163.com
地址:北京市朝阳区东四环中路78号楼(大成国际中心B1座)8B02室   邮编:100124
技术支持:北京玛格泰克科技发展有限公司
Copyright 2000-2014 版权所有 《中国当代医药》杂志社 未经授权请勿转载