Establishment of re-examination rules for automatic urine analyzer |
LI Qing1,2 WANG Fei1,2 HAN Shu-xia1,2 |
1.Department of Clinical Laboratory,Hubei Provincial Hospital of Traditional Chinese Medicine,Wuhan 430061,China;2.Hubei Institute of Traditional Chinese Medicine,Wuhan 430064,China |
|
|
Abstract Objective To establish a re-examination rule for the automatic urine analysis workstation consisting of Derry H-800 urine dry chemical analyzer and IRIS IQ-200 urine forming analyzer,and to verify the application of this rule in the clinic.Methods A total of 1715 specimens were tested by using this workstation.At the same time,each specimen was examined by urine sediments microscopic examination.Through the analysis of the test results of two methods,re-examination rules of the laboratory′s urine analysis workstation were developed and validated with 300 specimens.Results The results of the microscopic examination were taken as standards based on the examination of 1715 specimens.The false negative rate of the test results of urine analysis workstation was 1.22%,the false positive rate was 2.97%,and the re-examination rate was 33.41%.The results of the clinical specimen validation by the application of the re-examination rules were as follows:the false negative rate was 1.33%,the false positive rate was 1.66%and the re-examination rate was 35.33%.Conclusion The laboratory has developed and validated the re-examination rules for automated urine analysis workstation.The false negative rate,false positive rate and re-examination rate all can meet the requirements.This re-examination rule can be applied in clinical practice.
|
|
|
|
|
[1] |
中华人民共和国国家卫生和计划生育委员会医政医管局.全国临床检验操作规程[M].第4版.北京:人民卫生出版社,2015:171.
|
[2] |
刘成玉,罗春丽.临床检验基础[M].第5版.北京:人民卫生出版社,2012:166-167.
|
[3] |
杨晓波,王振楠.IQ 200尿沉渣分析仪中结果审核的必要性[J].中国医药导报,2011,8(6):153-154.
|
[4] |
丛玉隆.尿液有形成分检查及镜检筛选标准的制定[J].中华检验医学杂志,2011,34(6):481-482.
|
[5] |
王银锋,李锋,李想,等.尿常规复检规则的建立与验证[J].宁夏医学杂志,2014,36(5):429-431.
|
[6] |
鲍蕴文,孙龙乔子.IQ-200全自动尿沉渣分析仪镜检复检规则制订与应用[J].检验医学与临床,2013,10(21):2865-2867.
|
[7] |
吴鹏,谢世英,黄茜.迪瑞尿沉渣流水线用于尿液有形成分镜检筛选标准的研究[J].检验医学与临床,2015,12(24):3660-3663.
|
[8] |
马俊龙,丛玉隆,陆玉静,等.尿干化学与流式细胞术联合用于尿液有形成分镜检筛选的研究与应用[J].中华检验医学杂志,2011,34(6):494-500.
|
[9] |
梁红英,关植芝,杨丽红,等.建立尿液流水线尿沉渣分析仪检查结果复检规则的探讨[J].国际检验医学杂志,2016,37(13):1842-1843.
|
[10] |
梁肖云,黄镇华,张素娟,等妇女及儿童尿液分析复检规则的建立与应用[J].国际检验医学杂志,2016,37(6):797-799.
|
[11] |
张霞,李代碧,李倩.两种仪器在尿液分析中的综合应用[J].国际检验医学杂志 2016,37(17):2485-2486.
|
[12] |
吕纯莉,肖代敏,朱紹玲,等.URIT-1500尿干化学分析仪与AVE-764B尿有形成分分析仪联合尿液检测复检规则的制定和应用[J].检验医学,2016,31(1):45-48.
|
[13] |
刘万超,陈龙梅,杨振华,等.爱威尿液分析流水线镜检规则制订及验证[J].检验医学,2017,32(1):22-25.
|
[14] |
陈彩虹,曹利蕉,许庆丰,等.SYSMEX全自动尿液分析系统有形成分显微镜复检规则制定与验证[J].浙江医学教育,2016,15(4):52-54.
|
[15] |
赖利华,杨春燕,傅双双.常规尿液分析复检规则再评估、修订及验证[J].重庆医学,2016,45(19):2689-2692.
|
|
|
|